The OCW data printout is now available from the OCW dialog.
Changed default for one-touch scanning to "enabled".
Target printing now available without first starting new project.
Added option for ruler display box by the pointer.
Added hotkeys, '+' zoom in, and '-' zoom out.
Added "Show OCW Data" toolbar button, calls up the OCW by group
dialog. Use 'V' hotkey to show OCW by row.
Darkened the bullet holes on the virtual group and OCW printouts.
Added Target #9, 2x3 grid, 3.00" boxes.
Updated help system.
Changes for v3.70:
Added the offset distance for best score. Values are shown on
the target datasheet printout.
Added the "Adjust Brightness" tool. The tool automatically
adjusts the the image brightness to the correct level to
improve bullet hole detection.
Improved target printing to work with European paper sizes.
Fixed the datasheet printing from the main window.
Changes for v3.67:
Added the "Best" score calculation to the Group Information dialog.
It shows score calculated as if group was repositioned to maximize
the target score.
Added group distance calculation to the OCW information list.
Added the OCW print out showing information on each group
that was calculated.
Adjusted code for better target edge detection.
Changed target edge detection default setting to enabled.
Changed code to allow printing on A4 paper size.
Fixed point-of-aim drawing when in metric mode.
Added target style 19.
Changes for v3.66:
Changed scan commands. "Scan Target" button scans the entire
TDS target, 8.5" x 11.0" and reads the barcode. "Open From
Scanner" button shows the scanner UI to allow custom scanning
area and settings.
Added preliminary OCW datasheet printout with graphic.
OCW calculations include string distance from previous to next group.
Added a list box in OCW dialog showing the group average-to-center
size and string distance for each group.
Removed the Save Target File button from the TDS toolbar.
Fixed shot point export header to be correctly tab delimited
when exporting to the .txt file.
Added several new target definitions.
Changes for v3.65:
OCW test dialog will now calculate by-row or by-group from
the source target. The by-row display is only available if
the target is one of the custom TDS targets.
Hotkeys for OCW are; 'C' for by-group calculation, 'V' for
by-row calculation.
First group in OCW display has small blue circle drawn at
group center.
Changes for v3.64:
Added user setting to enable/disable target edge detection.
Improved target edge detection code.
Changes for v3.63:
TDS will now display the group information next to the
group on the main view. Click the "Show Info" checkbox
to show the text.
Exporting target and point data changed to tab-delimited
when the .txt file is selected. The .csv file export did
not change.
Option to reverse the y-axis values when exporting point
data. Added checkbox in the Tools/Options/Options tab.
Changed the "Open From Scanner" button to use the WIA
scanner interface and show the scanner UI. The "Scan Target"
button should be used for the TDS custom targets.
Added point data export button to the target data dialog.
Exported data will follow the current orientation setting.
Changed hotkeys: 'X' for ladder test dialog, 'C' for
OCW test dialog.
Target edge detection is now limited to targets that
have the box drawn between bulls.
Several new targets added.
Changes for v3.62:
Changed code to show the scan source dialog without checking
the source count.
Program will automatically find the top and left edges of the
scanned target image to compensate for targets that did not
print centered on the page.
Changes for v3.61:
Fixed point export function. It was not exporting the correct
value for the holes. The problem was only evident on target
images that were not scanned directly into the program (from
a camera or another scanning program and using a reference
distance).
Removed the Group Data By Row and Additional Group Data from
the target datasheet printout when the orientation is not set
to Top.
Added hotkeys, F4 to access the composite group dialog, F5
for the Ladder test display, and F6 for OCW test display.
Changes for v3.60:
Target data can be rotated from the inside the Target Data
dialog to match the direction the target was mounted on
the stand. The datasheet printout data will also be rotated
to the current orientation.
Improved manual entry of groups. All groups will be included
in the composite group data if an aim point is defined.
Added a "Print Data..." button in the Target Data dialog. Data
sheet can be printed without leaving the dialog.
Added an RBA 25 bull test target with sighters and blue rings.
New help file. The help file is still being written and will
be updated in future versions of TDS.
Changes for v3.59:
Bullet hole size and target distance are saved correctly
to the registry.
Previous versions only detected .224" holes. Changed program
to detect holes of current defined size.
Added checkbox to the options dialog to show the scanner
selection dialog if more than one source available.
The bull is now drawn correctly to scale when displaying
the composite group.
The composite group is correctly scaled to fit the display
area.
Sets the target style into the target notes field.
Added toolbar button to diaplay composite group dialog.
Shows the simulated ARA and PSL scores in the composite
grouop dialog.
Added text to the target number dialog explaining how to
enter the correct target style number.
Groups must have a defined point-of-aim to be added to
the composite group.
Target notes and text fields are printed on datasheet
The "set reference" tool has been improved.
Added several new target configurations.
Changes for v3.58:
Fixed a problem detecting multiple holes on one bull.
Improved bull detection accuracy.
Added TDS specific property page.
Simulated scoring for ARA and PSL practice targets (25 bulls only).